Airsight CO2 Monitor
A compact CO2 monitor with sleek display and up to 3 years long battery life
Know moreDevice
A high-precision IAQ Monitor with swappable sensor capsules and flexible connectivity options
Built with Nomestic's modular design, the Airsight Pro Monitor has two capsule slots. Replace a sensor capsule in seconds, without the need for traditional calibration, or add a new sensor capsule to monitor additional parameters. Use a slot for a battery capsule to keep the monitor running on battery backup for up to 1 hour.

The Airsight Monitor features a compact, understated design that blends effortlessly into any environment, from offices and classrooms to warehouses and hotel lobbies. Its discreet appearance maintains your interior aesthetics while delivering accurate, real-time indoor air quality data, ensuring effective monitoring without distracting from your space.

Connect the Airsight Pro Monitor over BACnet, Modbus, Ethernet, MQTT or API. It sends indoor air quality data to the Nomestic cloud for analysis and, at the same time, straight to your HVAC or building management system (BMS) for real-time control. It works with or without a BMS.

Power the Airsight Pro Monitor the way your building allows. Use PoE over the ethernet cable, a 24 V AC supply, 10 to 30 V DC wiring or a USB-C connection. With four options to choose from, you can install the monitor where it measures best, whether you are retrofitting an existing room or fitting out a new one.

Specifications
| Sensor | Type | Range | Resolution | Accuracy |
|---|---|---|---|---|
| Temperature | Digital CMOSens | -40 to 125 °C | 0.1 °C | ±0.2 °C |
| Humidity | Digital CMOSens | 0 to 100% RH | 0.01% RH | ±1.8% RH |
| Dust particles (PM2.5) | Light scattering | 0 to 1000 μg/m³ | 1 μg/m³ | 0-100 μg: ±10 μg/m³, 100-1000 μg: ±10% |
| Dust particles (PM10) | Light scattering | 0 to 1000 μg/m³ | 1 μg/m³ | 0-100 μg: ±10 μg/m³, 100-1000 μg: ±10% |
| Carbon dioxide (CO2) | NDIR | 400 to 3000 ppm | 1 ppm | ±40 ppm ±3% reading |
| Chemicals (TVOC index) | MOx MEMS | 0 to 500 | 1 | ≤ ±15 |
| NOx index | MOx MEMS | 0 to 500 | 1 | ≤ ±15 |
| Light | Photodiode | 1 to 83,000 lux | 1 lux | ±0.2% |
| Noise | Digital | 36 to 95 dB | 1 dB | ±3 dB @ 23 ±5 °C |
| Air pressure | Piezoresistive absolute pressure sensor (MEMS) | 300 to 1100 hPa | 0.01 hPa | ±1 hPa |
| Carbon monoxide (CO) | Micro fuel cell | 0 to 1000 ppm | 5 ppm | ±5 ppm or ±10% |
| Nitrogen dioxide (NO2) | Solid polymer electrochemical | 0 to 5 ppm | 0.001 ppm | 5% F.S |
| Ozone (O3) | Solid polymer electrochemical | 0 to 5 ppm | 0.001 ppm | 5% F.S |
Start Without Upfront Investment