Why a good energy label does not tell you how well a building runs

An energy label built on calculation describes typical use. Measured use can differ by a wide margin. What performance gap research and operational ratings show.

Two bars side by side: a short calculated bar labeled design and a taller measured bar labeled meter

An energy label based on calculation describes how a building is expected to perform under typical use. It does not describe how the building is run. The two can differ by a wide margin: according to Cohen et al. (2008), UK design studies in the late 1980s already found a large gap between simulated and observed energy use. This is usually called the performance gap. For anyone judging building performance, the label is one input and the meter is another.

What an energy label measures

The EU's Energy Performance of Buildings Directive (EU) 2024/1275 defines energy performance in Article 2(8) as "the calculated or metered amount of energy needed to meet the energy demand associated with a typical use of the building". It defines an energy performance certificate as a recognized certificate showing energy performance calculated under a methodology adopted under Article 4. So an EPC rests on a typical use of the building and says nothing about how a particular tenant uses it. That follows from the definitions.

Countries differ in how certificates are produced. In the UK, two kinds run side by side. An EPC gives an asset rating, which is calculated. A display energy certificate (DEC) gives an operational rating based on the metered energy used over the last 12 months, scaled so that 100 is typical for the building type, according to the UK government's guide (updated 2015). The guide ties DECs to buildings over 250 m2 that public authorities occupy and the public visits often. In Germany, section 79(1) of the Gebäudemodernisierungsgesetz, as shown on gesetze-im-internet.de, requires an energy certificate to be issued as either a demand certificate or a consumption certificate. dena's guide to the earlier GEG 2020 (4th edition) describes the demand certificate as calculated and the consumption certificate as based on measured consumption, and says the demand certificate gives an assessment independent of user behavior. In the US, the ENERGY STAR score runs from 1 to 100 and is built on measured energy data, adjusted for factors such as size, location, occupancy and weather, with 50 as the national median for similar buildings.

What the performance gap research found

The Carbon Trust's report Closing the gap (July 2011) drew on 28 case studies from the UK Low Carbon Buildings Programme and its own refurbishment work. It found that 75% of the case study designs did not perform as well as expected against relevant industry benchmarks. In one case, the design modeling for Part L and the EPC underestimated first-year energy use by a factor of five. On other projects with more detailed modeling and benchmarking, the gap still averaged 16%. Among the causes the report lists are design predictions that cover regulatory compliance and miss unregulated loads, extra occupancy and extra operating hours; design intent not delivered on site during construction; inadequate or incomplete commissioning; too little means of measuring and managing performance once the building is operating; and a building not operated properly by the facilities team or occupiers.

A 2016 review in Frontiers in Mechanical Engineering (van Dronkelaar et al.) focuses on UK non-domestic buildings, with case studies from several other countries. It reports that across 62 case-study buildings measured use averaged 34% above prediction, with a standard deviation of 55%. Nine of the 62 used twice the predicted energy and one used less than half. For offices the average was 22% above prediction (standard deviation 50%). The paper calls this the regulatory gap, because it compares the predictions of compliance models with metered use.

A conference paper by Menezes et al. (Loughborough University, ICAE 2011) links the gap to unrealistic assumptions about occupant behavior and facilities management. In a case study of one high-density office building, combining monitored data with energy modeling brought the model within 3% of actual electricity use.

A different kind of evidence comes from A tale of two buildings (JLL and the Better Buildings Partnership, 2012), which covers 225 London properties and more than 2 million m2 in 2011/2012. It found similar average consumption across EPC bands C, D and E, an E-rated building using less energy per m2 than a B-rated one, and the single most energy-intensive building rated C. The report concludes there is little or no correlation between EPC ratings and actual energy performance. The sample is London property held by 14 large owners over one year, and the report is an industry publication.

What a label cannot show about the rooms

The UK guide describes the DEC's main figure as an indicator of annual carbon dioxide emissions from the building's energy use. That is a statement about energy. This is reasoning from the definition, not a published finding: a low figure could come from good control, or from rooms that are under-ventilated or too cold, and a label cannot tell the two apart. The air side of that trade-off is covered in Net zero buildings still need clean air: how to do both.

Using the label and the meter together

The following is practical advice, not a finding from the studies. Treat the energy label as a statement about design and the meter as a statement about operation. Ask which kind of certificate a building holds and what use it assumed. Compare metered kWh per m2 with a benchmark for the building type, which is how both the DEC and the ENERGY STAR score work. Check operating hours against occupied hours, since the Carbon Trust names extra operating hours among the sources of the gap. CRREM pathways also take metered energy per m2 and year, as covered in ESG reporting for buildings: what data you actually need.

When a measure is installed, compare before and after from the same meters and sensors. The method is covered in How to verify ventilation savings with before and after sensor data. Nomestic measures indoor climate room by room, and savings are verified by comparing measured data before and after a change.